Casella CEL-352 dBadge Instruction Manual Page 1

Browse online or download Instruction Manual for Measuring, testing & control Casella CEL-352 dBadge. Casella CEL-352 dBadge Instruction manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 41
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Casella CEL-35X dBadge Users Handbook – Page 1
March 2010
CEL-350 dBadge &
CEL-352 dBadge ‘Plus’
Including Intrinsically Safe (I.S.)
Versions
Users Manual
HB3323-05
CASELLA CEL
Regent House,
Wolseley Road,
Kempston,
Bedford,
MK42 7JY, U.K.
Phone: +44 (0) 1234 844 100
Fax: +44 (0) 1234 841 490
E-mail: info@casellacel.com
Web: www.casellacel.com
CASELLA USA
17 Old Nashua Road,
# 15, Amherst,
NH 03031,
U.S.A.
Toll Free: +1 (800) 366 2966
Fax: +1 (603) 672 8053
E-mail: info@casellaUSA.com
Web: www.casellaUSA.com
CASELLA ESPANA
S.A.
Polígono Európolis
Calle C, nº4B
28230 Las Rozas - Madrid
Spain
Phone: + 34 91 640 75 19
Fax: + 34 91 636 01 96
E-mail: online@casella-es.com
Web: www.casella-es.com
Page view 0
1 2 3 4 5 6 ... 40 41

Summary of Contents

Page 1 - Versions

Casella CEL-35X dBadge Users Handbook – Page 1 March 2010 CEL-350 dBadge & CEL-352 dBadge ‘Plus’ Including Intrinsically Safe (I.S.) Ve

Page 2 - Environmental Considerations

Casella CEL-35X dBadge Users Handbook – Page 10 4 CHARGING THE CEL-35X 4.1 Charging The CEL-35X dBadge uses internal NiMH batteries. Ensu

Page 3

Casella CEL-35X dBadge Users Handbook – Page 11 Figure 6 Note that once removed from the charger, the dBadge will automatically sw

Page 4 - CONTENTS

Casella CEL-35X dBadge Users Handbook – Page 12 5 GENERAL OPERATION 5.1 Switching on the dBadge Once the instrument is switched on by pressing the

Page 5 - 1 INTRODUCTION

Casella CEL-35X dBadge Users Handbook – Page 13 Figure 9 The subsequent screens will cycle through results from the last measuremen

Page 6 - 2 SUPPLIED EQUIPMENT

Casella CEL-35X dBadge Users Handbook – Page 14 5.2 Calibration It is important to calibrate each dBadge before and after use, in accor

Page 7 - 3 THE SYSTEM COMPONENTS

Casella CEL-35X dBadge Users Handbook – Page 15 Figure 12 Press the ‘R’ key to confirm you wish to calibrate the unit, it will take a few

Page 8 - 3.3 The CEL-6362 Charger

Casella CEL-35X dBadge Users Handbook – Page 16 5.3 Starting A Measurement Run Ensure the windshield is fitted according to section 3.4.

Page 9 - 3.4 The Windshield

Casella CEL-35X dBadge Users Handbook – Page 17 Figure 16 Once the measurement run has begun, the ‘Play’ symbol will appea

Page 10 - 4 CHARGING THE CEL-35X

Casella CEL-35X dBadge Users Handbook – Page 18 Casella CEL recommends the dBadge is locked to prevent the wearer from tampering with the un

Page 11 - Figure 6

Casella CEL-35X dBadge Users Handbook – Page 19 5.4 Stopping A Measurement Run If the CEL-35X dBadge is locked, first unlock the keypad by

Page 12 - 5 GENERAL OPERATION

Casella CEL-35X dBadge Users Handbook – Page 2 Caution UNDER NO CIRCUMSTANCES should this equipment be cleaned using a solvent based cleaner.

Page 13 - Figure 10

Casella CEL-35X dBadge Users Handbook – Page 20 5.5 Reviewing Measurement Run Data As soon as a measurement run has been stopped, the dBadge will a

Page 14 - 5.2 Calibration

Casella CEL-35X dBadge Users Handbook – Page 21 By pressing the ‘R’ key when on any of these screens, the display will stop cycling for a period of 5

Page 15 - Figure 13

Casella CEL-35X dBadge Users Handbook – Page 22 On the language screen, the available options are English, Spanish, French, Italian, German

Page 16 - Figure 15

Casella CEL-35X dBadge Users Handbook – Page 23 For a definition of each of these terms please see Appendix 1, section 10.1. Note tha

Page 17 - DUR 07:45:12

Casella CEL-35X dBadge Users Handbook – Page 24 Display Setup Blue LED Off Blue LED Flashing Slow Blue LED Flashing Fast ISO Leq <=79.9dB(A) AND L

Page 18 - 07:55:12

Casella CEL-35X dBadge Users Handbook – Page 25 6 MOUNTING THE CEL-35X The recommended location for mounting a noise exposure meter varies dep

Page 19 - Figure 20

Casella CEL-35X dBadge Users Handbook – Page 26 Note, when any of the mounting clips are ordered, they are supplied in pa

Page 20 - OSHA View

Casella CEL-35X dBadge Users Handbook – Page 27 CEL-6354 Hard Hat Mounting Kit 6.3 CEL-6353 Harness Mounting Kit The CEL-6353 is used for atta

Page 21 - 5.6 Configuration Menu

Casella CEL-35X dBadge Users Handbook – Page 28 7 TECHNICAL SPECIFICATION 7.1 Specification Sound Exposure Meter/Dosimeter Standards: IEC 61252:

Page 22 - 5.7 Display Mode

Casella CEL-35X dBadge Users Handbook – Page 29 Overload Indication: 140.4dB RMS (i.e. 0.1dB above the top of the range), Peak Overload Value

Page 23 - 5.8 Alarm Settings

Casella CEL-35X dBadge Users Handbook – Page 3 Instructions specific to hazardous area installations (reference European ATEX Directive (94/9/EC, An

Page 24

Casella CEL-35X dBadge Users Handbook – Page 30 8 SERVICING AND WARRANTY ARRANGEMENTS To ensure conformity with the specification, this instr

Page 25 - 6 MOUNTING THE CEL-35X

Casella CEL-35X dBadge Users Handbook – Page 31 9 TROUBLESHOOTING Symptom Possible Cause Suggested Solution The dBadge will not switch on The dBa

Page 26 - Figure 24

Casella CEL-35X dBadge Users Handbook – Page 32 10 APPENDIX 10.1 Glossary of Terms This Appendix gives a glossary of the acoustic terminology used i

Page 27 - Figure 26

Casella CEL-35X dBadge Users Handbook – Page 33 Decibel (dB) The standard physical unit for measuring sound level and noise exposure. Estim

Page 28 - 7 TECHNICAL SPECIFICATION

Casella CEL-35X dBadge Users Handbook – Page 34 LAVG This is a parameter used in OSHA measurements. It is the average sound level over

Page 29

Casella CEL-35X dBadge Users Handbook – Page 35 Peak The maximum level in dB reached by the sound pressure at any instant during a measu

Page 30 - ARRANGEMENTS

Casella CEL-35X dBadge Users Handbook – Page 36 10.2 Measured Parameters Regardless of which display mode is selected (ISO or OSHA) ALL parameters

Page 31 - 9 TROUBLESHOOTING

Casella CEL-35X dBadge Users Handbook – Page 37 10.3 Using the CEL-352 for the Selection of Hearing Protection The CEL-352 dBadge ‘Plus’

Page 32 - 10 APPENDIX

Casella CEL-35X dBadge Users Handbook – Page 38 Where PNR is the predicted noise level reduction provided by the hearing protection. For example,

Page 33

Casella CEL-35X dBadge Users Handbook – Page 39 10.4 ATEX Certificate

Page 34

Casella CEL-35X dBadge Users Handbook – Page 4 CONTENTS 1 INTRODUCTION ...

Page 35

Casella CEL-35X dBadge Users Handbook – Page 40

Page 36 - 10.2 Measured Parameters

Casella CEL-35X dBadge Users Handbook – Page 41

Page 37 - Hearing Protection

Casella CEL-35X dBadge Users Handbook – Page 5 1 INTRODUCTION The CEL-35X family consists of the CEL-350 dBadge and the CEL-352 dBadge ‘Pl

Page 38

Casella CEL-35X dBadge Users Handbook – Page 6 2 SUPPLIED EQUIPMENT Carefully remove all components of the dBadge from the shipping container and

Page 39 - 10.4 ATEX Certificate

Casella CEL-35X dBadge Users Handbook – Page 7 Optional items at time of order: D8147/Z 3 Point Harness CEL-6351 Spare Pin Mounting Kit (5 Pac

Page 40

Casella CEL-35X dBadge Users Handbook – Page 8 Figure 2 3.3 The CEL-6362 Charger A CEL-6362 is a drop-in intelligent 3-way charger unit, required

Page 41

Casella CEL-35X dBadge Users Handbook – Page 9 charged in non-hazardous areas in the absence of any flammable atmospheres. 3.4 The Windshield Duri

Comments to this Manuals